BASIC INFO
Honeywell SPXCDASMRFDM ATEX, IECEx & AP approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input Transmitter with MODBUS, 2 x M20 Entries, 1 x M25 Entry, paited 316SS
Sensepoint XCD-RTD transmitter (use with oxygen and toxic Sensepoint sensors)
Sensepoint XCD-RTD (Remote Toxic Detector) allows for a gas sensor from a wider selection of 2-wire 4 to 20 mA input type Toxic and Oxygen sensors to be fitted directly to the transmitter housing, or wired remotely from another location.
KIT includes Transmitter, Magnetic Wand and Allen Key
Sensepoint XCD-RFD transmitter (use with Standard & Hi-Temp Sensepoint sensors)
Sensepoint XCD-RFD (Remote Flammable Detector) allows for remotely mounted flammable gas detectors
such as Hi-Temperature version of Sensepint Flamable to be located in adverse applications and monitored
from a convenient location.
KIT includes Transmitter, Magnetic Wand and Allen Key
| Sensepoint XCD-RTD transmitter (use with oxygen and toxic Sensepoint sensors) |
| Sensepoint XCD-RTD (Remote Toxic Detector) allows for a gas sensor from a wider selection of 2-wire 4 to 20 mA input type Toxic and Oxygen sensors to be fitted directly to the transmitter housing, or wired remotely from another location. KIT includes Transmitter, Magnetic Wand and Allen Key |
| INSTRUMENT |
| Without Modbus |
| SPXCDALMTX4 ATEX, IECEx & AP approved SP XCD-RTD 4~20mA Input Transmitter, 2 x M20 Entries, 1 x M25 Entry, painted LM25 |
| SPXCDASMTX4 ATEX, IECEx & AP approved SP XCD-RTD 4~20mA Input Transmitter, 2 x M20 Entries, 1 x M25 Entry, painted 316SS |
| SPXCDULNTX4 cCSAus approved SP XCD-RTD 4~20mA Input Transmitter, 3 x 3/4'' NPT Entries, painted LM25 |
| SPXCDUSNTX4 cCSAus approved SP XCD-RTD 4~20mA Input Transmitter, 3 x 3/4'' NPT Entries, painted 316SS |
| With Modbus |
| SPXCDALMTX4M ATEX, IECEx & AP approved SP XCD-RTD 4~20mA Input Transmitter with MODBUS, 2 x M20 Entries, 1 x M25 Entry, painted LM25 |
| SPXCDASMTX4M ATEX, IECEx & AP approved SP XCD-RTD 4~20mA Input Transmitter with MODBUS, 2 x M20 Entries, 1 x M25 Entry, painted 316SS |
| SPXCDULNTX4M cCSAus approved SP XCD-RTD 4~20mA Input Transmitter with MODBUS, 3 x 3/4'' NPT Entries, painted LM25 |
| SPXCDUSNTX4M cCSAus approved SP XCD-RTD 4~20mA Input Transmitter with MODBUS, 3 x 3/4'' NPT Entries, painted 316SS |
| Note: Refer to "Sensepoint" pricelist for the new M25 for ATEX/IECEx and 3/4''NPT for cCSA threaded range of Sensepoint Toxic sensors that may be fitted directly to the 4-20mA input XCD-RTD transmitter. |
| Sensepoint XCD-RFD transmitter (use with Standard & Hi-Temp Sensepoint sensors) |
| Sensepoint XCD-RFD (Remote Flammable Detector) allows for remotely mounted flammable gas detectors such as Hi-Temperature version of Sensepint Flamable to be located in adverse applications and monitored from a convenient location. KIT includes Transmitter, Magnetic Wand and Allen Key |
| INSTRUMENT |
| Without Modbus |
| SPXCDALMRFD ATEX, IECEx & AP approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input Transmitter, 2 x M20 Entries,1 x M25 Entry,painted LM25 |
| SPXCDASMRFD ATEX, IECEx & AP approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input Transmitter, 2 x M20 Entries,1 x M25 Entry,painted 316SS |
| SPXCDULNRFD cCSAus approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input Transmitter, 3 x 3/4'' NPT Entries, painted LM25 |
| SPXCDUSNRFD cCSAus approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input Transmitter, 3 x 3/4'' NPT Entries, painted 316SS |
| With Modbus |
| SPXCDALMRFDM ATEX, IECEx & AP approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input Transmitter with MODBUS, 2 x M20 Entries, 1 x M25 Entry, paited LM25 |
| SPXCDASMRFDM ATEX, IECEx & AP approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input Transmitter with MODBUS, 2 x M20 Entries, 1 x M25 Entry, paited 316SS |
| SPXCDULNRFDM cCSAus approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input Transmitter with MODBUS, 3 x 3/4'' NPT Entries, painted LM25 |
| SPXCDUSNRFDM cCSAus approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input Transmitter with MODBUS, 3 x 3/4'' NPT Entries, painted 316SS |
| Remote Flammable Sensor (XCD Sensor Cartridge + Socket Housing) |
| SPXCDXSRFXSS Flammable CAT 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) Sensor Cartridge with Socket Housing |
| SPXCDXSRRXSS Methane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) Sensor Cartridge with Socket Housing |
| SPXCDXSRPXSS Propane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) Sensor Cartridge with Socket Housing |
| SPXCDXSRB1SS Carbon Dioxide IR 0-2.00%VOL only with Socket Housing Sensor Cartridge with Socket Housing |
| SPXCDXSRB2SS Carbon Dioxide IR 0-5.00%VOL only with Socket Housing Sensor Cartridge with Socket Housing |
| 00780-A-0100 Term Hsg-Bartec DE1155 With Continuity Plate 1x25mm- 3x20mm Entries (ATEX certified) |