Yokogawa YS110 Standby Manual Station

description:If a YS1360, YS136, YS1500, YS150, YS1700, or YS170 instruments fails, the YS110 Standby Manual Station can be used to output a 4 to 20 mA signal to the control valve actuator instead of the instruments....
BASIC INFO

Yokogawa YS110 Standby Manual Station

 

 

 

 If a YS1360, YS136, YS1500, YS150, YS1700, or YS170 instruments fails, the YS110 Standby Manual Station can be used to output a 4 to 20 mA signal to the control valve actuator instead of the instruments. This standby manual station can be connected to YS1360, YS136, YS1500, YS150, YS1700, or YS170 instruments by swinging up the front display, then the instrument can be exchanged (the output is back up by the YS110), YS110 is battery operated; it can also be plugged into the instrument case and operated off the system power supply.

 


STANDARD SPECIFICATION
1. Input/MV Signals Specification
Input signal : 1 to 5 V DC, 1 point
MV output signal : 4 to 20 mA DC, 1 point
Input/MV indicator : Indicator Moving coil type
Range : 0 to 100 %
Scale : 20 equal divisions
MV operation : Manual operation by operation
wheel (on the front panel)
I/O Connection : Connected to connector on the
controller case by supplied cable
Controller for backed up : YS1360, YS136, YS1500,
YS150, YS1700, YS170


2. Power Supply Specification
2.1 Internal Power Supply
Continued operation with the internal batteries : 1
hour (with new batteries max.)
Battery : 6F22 (IEC Type), 9V dry sell, three required
Battery check : provided
Push the battery check switch to display the remaining
life of the internal battery. If the indicator indicates
more than 75% of span, you can continue using this
battery.


2.2 External Power Supply
When installed in the YS1360, YS136, YS1500,
YS150, YS1700, or YS170 case, power is supplied
via the connector in the back of the instruments, and
the internal battery is disconnected.
Rated Power Supply Voltage: For both DC and AC
100 V version;
DC drive; 24-120 V DC (±10%), no polarity
AC drive; 100-120 V AC (±10%), 50/60 Hz (±3Hz)
220 V version;
DC drive; 135-190 V DC (±10%), no polarity
AC drive; 220-240 V AC (±10%), 50/60 Hz (±3Hz)
On the other hand, the instruments themselves have
the ability to operate under the condition as shown
below which is the same as the former description of
the power supply voltage.

 

Usable Power Supply Voltage: For both DC and AC

100 V version;
DC drive; 20-130 V DC, no polarity
AC drive; 80-138 V AC, 47-63 Hz
220 V version;
DC drive; 120-340 V DC, no polarity
AC drive; 138-264 V AC, 47-63 Hz


3. Dimensions, Mounting
Portable (can be installed in YS1500, YS150,
YS1700, or YS170 case)
Signal cable length: 2 m
External dimensions: 144 x 58 x 295 (mm)
Weight: 1.6 kg

 

 

-----------------------------------